Bio-rad Bio-Scale™ MT High-Resolution Empty Columns Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Strumenti di misura Bio-rad Bio-Scale™ MT High-Resolution Empty Columns. Bio-Rad Bio-Scale™ MT High-Resolution Empty Columns User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Bio-Scale
MT
Columns
Instruction Manual
Catalog numbers
751-0081
751-0083
751-0085
751-0087
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - Bio-Scale

Bio-Scale™ MT ColumnsInstruction ManualCatalog numbers751-0081751-0083751-0085751-0087

Pagina 2

6 Bio-Scale MT Column Instruction Manual5. Attach the column to a pump and start flow at 50% of the desired operating flow rate.6. When all the air

Pagina 3 - Table of Contents

Bio-Scale MT Column Instruction Manual 78. Pass 5 bed volumes of buffer through the column at a flow rate 20% higher than the operating flow rate. 9.

Pagina 4

8 Bio-Scale MT Column Instruction ManualSection 3Care of the Bio-Scale MT Columns3.1 Frit RemovalThe top frit may need to be replaced after extens

Pagina 5 - Section 1

Bio-Scale MT Column Instruction Manual 9Section 4Solvent Compatibility TableTable 2. Solvent Compatibility.SolventsAcetic acid (50%)AcetonitrileButa

Pagina 6 - 1.3 Column Specifications

10 Bio-Scale MT Column Instruction ManualSection 5Product InformationCatalogNumberProduct DescriptionBed Dimension, mmBed Volume, mlPressure Limit,

Pagina 7 - Use of Bio-Scale MT Columns

Bio-Scale MT Column Instruction Manual 11

Pagina 8 - 2.2 Column Assembly

Life ScienceGroupSig 12134006044 Rev B US/EGBio-Rad Laboratories, Inc.Web site www.bio-rad.com USA 800 424 6723 Australia 61 2 9914 2800 Austri

Pagina 10 - Slurry Packing

Table of ContentsSection 1 Characteristics of Bio-Scale MT2, MT5, MT10, and MT20 Columns ... 11.1 Introduction ...

Pagina 12 - Section 3

Bio-Scale MT Column Instruction Manual 1Section 1 Characteristics of the Bio-Scale MT2, MT5, MT10, and MT20 Columns1.1 IntroductionThe Bio-Scale MT

Pagina 13 - Solvent Compatibility Table

2 Bio-Scale MT Column Instruction Manual1.3 Column SpecificationsAll wetted parts are bio-compatible (Tefzel, polypropylene, polyphenyl sulfide, bor

Pagina 14 - Product Information

Bio-Scale MT Column Instruction Manual 3Section 2Use of Bio-Scale MT ColumnsFig. 1. Diagram of Bio-Scale MT Column.FLOWUpper end fitting (1)Upper end

Pagina 15

4 Bio-Scale MT Column Instruction Manual2.1 Column Disassembly (part given are in parenthesis)1. Unscrew and remove the upper (1) and lower (11)

Pagina 16 - Bio-Rad

Bio-Scale MT Column Instruction Manual 59. Gently turn the lock nut until the upper bed support is in the desired position.10. Attach upper (1) and

Commenti su questo manuale